December 30, 2025
Jackson taught me
Lapping length is 40dia
said rebar is 16mm
Lapping length 16 x 40 = 640
this is the length to overlap a cut rebar on structural wall.
In this case, the contractor accidentally hacked the load bearing shear wall, not only that and he also cut off one of the rebar. We need to replace the rebar, by overlapping (not weld, as welding will weaken the bar strength) a new rebar.
The bigger the rebar, the more depth need to plant.