Month: December 2025

Jackson taught me

Lapping length is 40dia said rebar is 16mm Lapping length 16 x 40 = 640 this is the length to overlap a cut rebar on structural wall. In this case, the contractor accidentally hacked the load bearing shear wall, not only that and he also cut off one of the rebar. We need to replace

150mm Concrete Testing Cube Mould @ Puchong

150 mm Square Concrete Test Cube Mould @ Puchong Product Description:Our 150 mm square concrete test cube moulds are designed for precision and durability in concrete testing laboratories. Manufactured from high-quality steel or polypropylene, these moulds ensure accurate and consistent cube dimensions for compressive strength testing. Their smooth internal surfaces facilitate easy de-moulding and minimize the risk

2000L – 4000L Diesel Skid Tank Puchong

We fabricate storage skid tank here in Taman Perindustrian Puchong. Selecting the right diesel skid tank often comes down to balancing storage capacity, transport limits, and available site space. A common constraint is keeping the tank diameter at 1200 mm, which provides good stability while remaining easy to transport and install. With a fixed diameter,